{"id":15573,"date":"2020-08-29T08:13:58","date_gmt":"2020-08-29T08:13:58","guid":{"rendered":"http:\/\/incontrol-co.com\/?page_id=15573"},"modified":"2022-02-19T16:31:48","modified_gmt":"2022-02-19T16:31:48","slug":"mc-1120-2","status":"publish","type":"page","link":"https:\/\/incontrol-co.com\/index.php\/mc-2021\/mc-1120-2\/","title":{"rendered":"MC-1120"},"content":{"rendered":"\n<p><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-1 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>Overview<\/p>\n\n\n\n<p>MC-1120 is wireless and wired smart controller application for Automatic fire fighting monitors. It\u2019s comprehensive functionality and great ease of use make it a highly cost\u2013efficient solution for virtually any remote foam \/ water monitor application. This controller can be controlled up to 5 actuators in same time via wireless remote control (RC1120) or fix console joystick. <\/p>\n\n\n\n<p>These controller includes:<\/p>\n\n\n\n<ol type=\"1\"><li>&nbsp;10Ch. Line monitoring 24Vdc power output switch to connect directly to relay our contactor coil up to 500mA.<\/li><li>10Ch. Opto-Isolation input to receive actuator feedback<\/li><li>14Ch.&nbsp; Opto-Isolation input and 14Ch O\/C output to connect joystick, push buttons &amp; indicators in front of fix console<\/li><li>2.4Ghz wireless transducer to communication with RC1120 remote controller.<\/li><\/ol>\n\n\n\n<ul><li>Benefit:<\/li><li>No need programming in the plant (fully programed).<\/li><li>High reliability and minimal maintenance.<\/li><li>Small physical size.<\/li><li>Wireless module included.<\/li><li>low initial investment cost.<\/li><\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/incontrol-co.com\/wp-content\/uploads\/2020\/09\/3-scaled.jpg\" alt=\"\" class=\"wp-image-15722\" width=\"355\" height=\"229\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/incontrol-co.com\/wp-content\/uploads\/2020\/09\/F036CF8F-D4AB-4E63-A15A-29A658AC55E0-768x1024.jpeg\" alt=\"\" class=\"wp-image-15761\" width=\"356\" height=\"474\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p>You can find information on terminal wiring in the MC-1120 as below table:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><a>&nbsp;<\/a><\/td><td>Port Description<\/td><td>I\/O<\/td><td>Terminal No.<\/td><td>signal type<\/td><td>to\/from<\/td><\/tr><tr><td>1<\/td><td>Left Command<\/td><td>Out<\/td><td>1<\/td><td>(+)<\/td><td>to 24vdc contactor<\/td><\/tr><tr><td>2<\/td><td>Right Command<\/td><td>Out<\/td><td>2<\/td><td>(+)<\/td><td>to 24vdc contactor<\/td><\/tr><tr><td>3<\/td><td>&nbsp;Up Command<\/td><td>Out<\/td><td>3<\/td><td>(+)<\/td><td>to 24vdc contactor<\/td><\/tr><tr><td>4<\/td><td>Down Command<\/td><td>Out<\/td><td>4<\/td><td>(+)<\/td><td>to 24vdc contactor<\/td><\/tr><tr><td>5<\/td><td>&nbsp;Motor Fog Command<\/td><td>Out<\/td><td>5<\/td><td>(+)<\/td><td>to 24vdc contactor<\/td><\/tr><tr><td>6<\/td><td>&nbsp;Motor Jet Command<\/td><td>Out<\/td><td>6<\/td><td>(+)<\/td><td>to 24vdc contactor<\/td><\/tr><tr><td>7<\/td><td>Water MOV Open Command<\/td><td>Out<\/td><td>7<\/td><td>(+)<\/td><td>to 24vdc contactor<\/td><\/tr><tr><td>8<\/td><td>Water MOV Close Command<\/td><td>Out<\/td><td>8<\/td><td>(+)<\/td><td>to 24vdc contactor<\/td><\/tr><tr><td>9<\/td><td>Foam MOV Open Command<\/td><td>Out<\/td><td>9<\/td><td>(+)<\/td><td>to 24vdc contactor<\/td><\/tr><tr><td>10<\/td><td>Foam MOV Close Command<\/td><td>Out<\/td><td>10<\/td><td>(+)<\/td><td>to 24vdc contactor<\/td><\/tr><tr><td>11<\/td><td>Left Status<\/td><td>In<\/td><td>11<\/td><td>(+)<\/td><td>from Actuator limit switch<\/td><\/tr><tr><td>12<\/td><td>Right Status<\/td><td>In<\/td><td>12<\/td><td>(+)<\/td><td>from Actuator limit switch<\/td><\/tr><tr><td>13<\/td><td>&nbsp;Up Status<\/td><td>In<\/td><td>13<\/td><td>(+)<\/td><td>from Actuator limit switch<\/td><\/tr><tr><td>14<\/td><td>Down Status<\/td><td>In<\/td><td>14<\/td><td>(+)<\/td><td>from Actuator limit switch<\/td><\/tr><tr><td>15<\/td><td>&nbsp;Motor Fog Status<\/td><td>In<\/td><td>15<\/td><td>(+)<\/td><td>from Actuator limit switch<\/td><\/tr><tr><td>16<\/td><td>&nbsp;Motor Jet Status<\/td><td>In<\/td><td>16<\/td><td>(+)<\/td><td>from Actuator limit switch<\/td><\/tr><tr><td>17<\/td><td>Water MOV Open Status<\/td><td>In<\/td><td>17<\/td><td>(+)<\/td><td>from Actuator limit switch<\/td><\/tr><tr><td>18<\/td><td>Water MOV Close Status<\/td><td>In<\/td><td>18<\/td><td>(+)<\/td><td>from Actuator limit switch<\/td><\/tr><tr><td>19<\/td><td>Foam MOV Open Status<\/td><td>In<\/td><td>19<\/td><td>(+)<\/td><td>from Actuator limit switch<\/td><\/tr><tr><td>20<\/td><td>Foam MOV Close Status<\/td><td>In<\/td><td>20<\/td><td>(+)<\/td><td>from Actuator limit switch<\/td><\/tr><tr><td>21<\/td><td>Left Joystick Command Station<\/td><td>In<\/td><td>21<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>22<\/td><td>Right&nbsp; Joystick&nbsp; Command Station<\/td><td>In<\/td><td>22<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>23<\/td><td>&nbsp;Up Joystick&nbsp; Command Station<\/td><td>In<\/td><td>23<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>24<\/td><td>Down Joystick&nbsp; Command Station<\/td><td>In<\/td><td>24<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>25<\/td><td>&nbsp;Motor Fog Joystick&nbsp; Command Station<\/td><td>In<\/td><td>25<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>26<\/td><td>&nbsp;Motor Jet Joystick&nbsp; Command Station<\/td><td>In<\/td><td>26<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>27<\/td><td>Water MOV Open Joystick&nbsp; Command Station<\/td><td>In<\/td><td>27<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>28<\/td><td>Water MOV Close Joystick&nbsp; Command Station<\/td><td>In<\/td><td>28<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>29<\/td><td>Foam MOV Open Joystick&nbsp; Command Station<\/td><td>In<\/td><td>29<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>30<\/td><td>Foam MOV Close Joystick&nbsp; Command Station<\/td><td>In<\/td><td>30<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>31<\/td><td>Emergency Stop Command Station<\/td><td>In<\/td><td>31<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>32<\/td><td>Enable \/ Disable Command Station<\/td><td>In<\/td><td>32<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>33<\/td><td>Oscillating<\/td><td>In<\/td><td>33<\/td><td>(+)<\/td><td>from joystick on command station<\/td><\/tr><tr><td>34<\/td><td>Com. Fault<\/td><td>In<\/td><td>34<\/td><td>(+)<\/td><td>from fault contact<\/td><\/tr><tr><td>35<\/td><td>Left Indicator&nbsp; Command Station<\/td><td>Out<\/td><td>35<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>36<\/td><td>Right Indicator&nbsp; Command Station<\/td><td>Out<\/td><td>36<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>37<\/td><td>Up Indicator&nbsp; Command Station<\/td><td>Out<\/td><td>37<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>38<\/td><td>Down Indicator Command Station&nbsp;<\/td><td>Out<\/td><td>38<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>39<\/td><td>&nbsp;Motor Fog Indicator&nbsp; Command Station<\/td><td>Out<\/td><td>39<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>40<\/td><td>&nbsp;Motor Jet Indicator&nbsp; Command Station<\/td><td>Out<\/td><td>40<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>41<\/td><td>Water MOV Open Indicator&nbsp; Command Station<\/td><td>Out<\/td><td>41<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>42<\/td><td>Water MOV Close Indicator&nbsp; Command Station<\/td><td>Out<\/td><td>42<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>43<\/td><td>Foam MOV Open Indicator&nbsp; Command Station<\/td><td>Out<\/td><td>43<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>44<\/td><td>Foam MOV Close Indicator&nbsp; Command Station<\/td><td>Out<\/td><td>44<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>45<\/td><td>Fault Indicator Command Station<\/td><td>Out<\/td><td>45<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>46<\/td><td>Enable \/ Disable Indicator Command Station<\/td><td>Out<\/td><td>46<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>47<\/td><td>Oscillating indecator command station<\/td><td>Out<\/td><td>47<\/td><td>open collector (-)<\/td><td>to 24Vdc indicator on command station<\/td><\/tr><tr><td>48<\/td><td>sensor off (if any)<\/td><td>Out<\/td><td>48<\/td><td>open collector (-)<\/td><td>to 24vdc relay(if any)<\/td><\/tr><tr><td>49<\/td><td>Switching Power Supply Positive Voltage<\/td><td>24Vdc<\/td><td>&nbsp;&nbsp; +<\/td><td><\/td><td><\/td><\/tr><tr><td>50<\/td><td>Switching Power Supply Negative Voltage<\/td><td>&nbsp;&nbsp; &#8211;<\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Specification<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Output signal &nbsp;<\/strong><\/td><td>10 Ch. Line monitoring output (max 500mA output for each channel) 14 open collector output<\/td><\/tr><tr><td><strong>Input signal<\/strong><\/td><td>24 Ch. Opto-Isolation input<\/td><\/tr><tr><td><strong>Command station operation joystick\/switch &amp; indicator which has the ability to connect to MC1120 &nbsp;&nbsp;&nbsp;<\/strong><strong><\/strong><\/td><td>Left \/ Right \u2013 Up \/ Down joystick &amp; feedback indicators Water actuator valve open\/close pushbutton &amp; feedback indicators Foam actuator valve open \/ close pushbutton &amp; feedback indicators Fog &amp; jet pushbutton &amp; feedback indicators Oscillating mode pushbutton &amp; feedback indicator On\/off switch with related indicator Fault indicator Emergency shutdown pushbutton<\/td><\/tr><tr><td><strong>Operation voltage<\/strong><\/td><td>Normal 24Vdc (18 ~28Vdc)<\/td><\/tr><tr><td><strong>Controller Power consumption<\/strong><\/td><td>Max 550mA<\/td><\/tr><tr><td><strong>Dimension<\/strong><\/td><td>L:220mm&nbsp;&nbsp; W:150mm H: 42mm<\/td><\/tr><tr><td><strong>Installation<\/strong><\/td><td>Din rail<\/td><\/tr><tr><td><strong>Weight<\/strong><\/td><td>600 g<\/td><\/tr><tr><td><strong>Frequency Band \/ receiver sensitivity<\/strong><\/td><td>2.4GHz&nbsp; \/ -98dBm<\/td><\/tr><tr><td><strong>Operating Temperature<\/strong><\/td><td>-40 to 60\u00b0C<\/td><\/tr><tr><td><strong>Reaction Time<\/strong><\/td><td>&lt; 0.1 Sec<\/td><\/tr><tr><td><strong>Max Distance coverage area for wireless<\/strong><\/td><td>Visual distance 1500 meter in open area with 10dB antenna<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Overview MC-1120 is wireless and wired smart controller application for Automatic fire fighting monitors. It\u2019s comprehensive functionality and great ease of use make it a highly cost\u2013efficient solution for virtually any remote foam \/ water monitor application. This controller can be controlled up to 5 actuators in same time via wireless remote control (RC1120) or [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":15576,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"_links":{"self":[{"href":"https:\/\/incontrol-co.com\/index.php\/wp-json\/wp\/v2\/pages\/15573"}],"collection":[{"href":"https:\/\/incontrol-co.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/incontrol-co.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/incontrol-co.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/incontrol-co.com\/index.php\/wp-json\/wp\/v2\/comments?post=15573"}],"version-history":[{"count":12,"href":"https:\/\/incontrol-co.com\/index.php\/wp-json\/wp\/v2\/pages\/15573\/revisions"}],"predecessor-version":[{"id":16123,"href":"https:\/\/incontrol-co.com\/index.php\/wp-json\/wp\/v2\/pages\/15573\/revisions\/16123"}],"up":[{"embeddable":true,"href":"https:\/\/incontrol-co.com\/index.php\/wp-json\/wp\/v2\/pages\/15576"}],"wp:attachment":[{"href":"https:\/\/incontrol-co.com\/index.php\/wp-json\/wp\/v2\/media?parent=15573"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}